Pre-Terminated MTP®/MPO and LC Trunk Cable, 8 to 144 Fibers, for Data Center Backbone Links

How can MTP/MPO Trunk Cable, OM5 (lime green) support your network infrastructure requirements?

MTP®/MPO Trunk Cable - MTP/MPO Trunk Cable, OM5 (lime green)
  • MTP®/MPO Trunk Cable - MTP/MPO Trunk Cable, OM5 (lime green)
  • MTP/MPO Trunk Cable, OM3 (aqua)
  • MTP/MPO Trunk Cable, OM4 (violet)
  • MTP/MPO Trunk Cable, OS2 single mode (yellow)

MTP®/MPO Trunk Cable

Pre-Terminated MTP®/MPO and LC Trunk Cable, 8 to 144 Fibers, for Data Center Backbone Links

MTP®/MPO trunk cables deploy a high-density permanent link in a single factory-terminated assembly — 8 to 144 fibers between two distribution areas, with MTP®/MPO or LC on each end. Staggered breakout legs are cut to your rack layout, polarity is specified at order (Type A, B or C), and every assembly is terminated and tested before shipment, so the backbone goes in without field splicing.

SKU

004 Series

Specifications
  • Fiber counts: 8, 12, 24, 36, 48, 60, 72, 84, 96, 108, 120, 132 and 144 fibers.
  • Connector type on each end: MTP®/MPO or LC. Example build: 48 fibers as 4 × 12F MPO legs on each end.
  • Fiber types: OM3, OM4 and OM5 bend-insensitive multimode (BIMMF), and OS2 G.657.A single mode.
  • Polarity: Type A, Type B, Type C, or customized — as defined in ANSI/TIA-568.3-E.
  • MTP®/MPO connector options: US Conec MTP® or MPO-compatible; male (with pins) or female (unpinned).
  • Performance grades: Standard Loss and Low Loss — see the insertion loss and return loss tables.
  • Breakout: staggered leg lengths, cut to your panel or cassette layout.
  • Testing: every assembly is individually tested before shipment and ships with its own test report.
  • Cable jacket: LSFRZH. Other jacket materials available on request.
  • Operating temperature: −20 °C to +70 °C. Storage temperature: −40 °C to +80 °C.
  • Pulling eye, further assemblies, breakout length and cable length available on request.
Mechanical Characteristics
  • Reliable high-density interconnection for: data center main, horizontal and zone distribution areas; data communications networks, including interconnections for parallel optical transmitters and receivers; telecommunications networks and broadband/CATV networks.
Note
  • Fiber Compatibility: OM3, OM4, OM5 (BIMMF) and OS2 G.657.A

Which Pre-Terminated Assembly Do You Need?

Trunk, array and harness assemblies are built from the same MTP®/MPO connectivity but play different roles in the link. Choose by what sits at each end.

AssemblyEnd AEnd BTypical role
MTP®/MPO Trunk Cable (this page)Multiple MTP®/MPO or LC legsMultiple MTP®/MPO or LC legsPermanent backbone between two distribution areas, up to 144 fibers in one cable
MTP®/MPO Array CableOne MTP®/MPOOne MTP®/MPOSingle 12F to 32F link, including direct transceiver connection
MTP®/MPO to LC / SC HarnessOne MTP®/MPOLC or SC legsBreakout from a parallel link to duplex equipment ports

MTP®/MPO Insertion Loss and Return Loss Grades

Maximum insertion loss per MTP®/MPO connector mating, with the minimum return loss for each grade.

Grade / Fiber TypeStandard LossLow Loss
Insertion loss — BIMMF OM3 / OM4 / OM5 (Multimode)≤ 0.50 dB≤ 0.35 dB
Insertion loss — SM OS2 G.657.A (Single-mode)≤ 0.75 dB≤ 0.35 dB
Return loss — BIMMF OM3 / OM4 / OM5 (Multimode)≥ 20 dB≥ 20 dB
Return loss — SM OS2 G.657.A (Single-mode)≥ 60 dB≥ 60 dB

LC Insertion Loss and Return Loss Grades

For trunk cables terminated with LC connectors on one or both ends.

Grade / Fiber TypeStandard LossLow Loss
Insertion loss — BIMMF OM3 / OM4 / OM5 (Multimode)≤ 0.30 dB≤ 0.15 dB
Insertion loss — SM OS2 G.657.A (Single-mode)≤ 0.20 dB≤ 0.15 dB
Return loss — BIMMF OM3 / OM4 / OM5 (Multimode)≥ 35 dB≥ 35 dB
Return loss — SM OS2 G.657.A (Single-mode)≥ 55 dB≥ 55 dB

These are EXW product grades. ANSI/TIA-568.3-E Annex A sets a maximum of 0.75 dB insertion loss per mated connector pair, applying the same limit to MPO array connectors and single-fiber connectors.

How to Order an MTP®/MPO Trunk Cable

Each trunk cable is built to order. Specify the following when requesting a quotation so the assembly arrives ready to install without field adaptation.

StepParameterOptions
1Total fiber count8 / 12 / 24 / 36 / 48 / 60 / 72 / 84 / 96 / 108 / 120 / 132 / 144
2Fiber modeSingle mode: OS2 G.657.A (yellow). Multimode: OM3 (aqua), OM4 (violet), OM5 (lime green).
3Connector on each endMTP®/MPO (US Conec MTP® or MPO-compatible; male or female) or LC
4PolarityType A / Type B / Type C / Customized
5Performance gradeStandard Loss / Low Loss
6Breakout leg lengthsStaggered lengths per end, to match your panel or cassette layout
7Overall lengthFeet / Meters

MTP® is a registered trademark of US Conec Ltd.

Related Products
MTP®/MPO Array Cable - MTP/MPO Array Cable
MTP®/MPO Array Cable

Every array cable is factory-terminated and individually tested before shipment, so link loss...

Details Add to List
Fiber Optic MTP® / MPO to LC  / SC Harness - 005 Series Fiber Direct Harness
Fiber Optic MTP® / MPO to LC / SC Harness

005 direct harness has a pinned (male) MTP®/MPO connector on one end and while the other end is equipped...

Details Add to List
Fiber Optic Trunk Harness Cable - MTP/MPO Fiber Patch Cable Trunk Harness
Fiber Optic Trunk Harness Cable

008 series is for backbone installation. EXW provides a complete set of choices for fber connectors...

Details Add to List
Harness Fiber Patch Cable - 006 Series Fiber Optic Cable Harness
Harness Fiber Patch Cable

006 harness series is for transition from trunk backbone assemblies to fiber rack system. MTP®/MPO...

Details Add to List
Fiber Optic Mini Breakout Cable - 002 Series Mini Break Out Cable
Fiber Optic Mini Breakout Cable

002 mini break out cable is the very compact and space saving cable distributor because the cable...

Details Add to List
FAQ
Category 8 Solutions for Future Networks

Category 8 RJ45 solutions are designed to support Ethernet at rate up to 40 Gbps (40GBASE-T) for short distances up to 30 meters, which is a solution primarily...

All of EXW Patch Cords Use Bare Copper Wires

All of EXW patch cords use pure bare copper wires. EXW patch cords do not use CCA (copper clad aluminum) wires nor do we recommend using patch cords made...

Files Download
Trunk 48C (4x12C) OM4 MPO(M) to MPO(M) B Type
Trunk 48C (4x12C) OM4 MPO(M) to MPO(M) B Type

Example drawing: 48-fiber OM4 trunk, 4 x 12F MPO male legs on each end, Type B polarity

Download
MTP MPO Trunk Cable Spec Sheet
MTP MPO Trunk Cable Spec Sheet

MTP®/MPO and LC trunk cables, 8 to 144 fibers, OM3/OM4/OM5 and OS2 G.657.A

Download

How can MTP®/MPO Trunk Cable support your network infrastructure requirements?

EXW provides MTP®/MPO Trunk Cable for professional network infrastructure, data center, telecommunications, and connectivity applications. Designed to support reliable installation and integration, this product can be incorporated into a wide range of network projects according to specific system, application, and deployment requirements. Our team works with customers to identify suitable product configurations for new installations, infrastructure upgrades, and customized networking projects.

MTP®/MPO Trunk Cable is suitable for data center operators, telecommunications providers, system integrators, network installers, distributors, and other professional buyers seeking dependable network infrastructure solutions. Product specifications, configurations, quantities, and customization requirements can be discussed according to your project needs. Contact EXW for product information, technical details, availability, and assistance in selecting the appropriate solution for your network application.