Cat.5E FTP 90 Degree Inline Coupler
RJ45 Cat5E Shielded 90 Degree Etherner Coupler for LAN Cable
Ideal for linking two cables without a hub, the RJ45 inline coupler provides a 90 degree end-to-end connection that allows the cable to be organized in various ways while the reliability remains. It is compact and slim that it fits right into a blank panel. The Press-Fit technology requires no solder, so the inline coupler is lead-free.
SKU
3D01-B01-00010
Mechanical Characteristics
- Insertion lifespan: 750 cycles with a FCC compliant RJ45 plug.
- Contact Force: 100 Grams With a FCC Compliant RJ-45 Plug.
- Plug retention force: 11 lbf min.
- Operating temperature range: -10°C To 60°C.
- Storage temperature range: -40°C To 68°C.
- Humidity: 10% ~ 90% RH.
Electrical Characteristics
- Insulation Resistance: 500 MΩ
- Dielectric Withstanding Voltage: 1,000 V AC
- DC Current Rating: 1.5 Amps.
- DC Resistance: 0.1 Ω
- Contact Resistance: 20 mΩ
- Related Products
Cat.5E UTP 90 Degree Inline Coupler
Providing the female-to-female connection, the 90 degree inline coupler is the best choice...
Details Add to ListCat.6 FTP 90 Degree Inline Coupler
Providing a female-to female feed-through connection between two patch cables, the Cat6 inline...
Details Add to ListCat.6 UTP 180 Degree Inline Coupler
Providing a female-to female feed-through connection between two patch cables, the Cat6 inline...
Details Add to ListCat.6A UTP 90 Degree Inline Coupler
Providing a female-to female feed-through connection between two patch cords, the Cat.6 inline...
Details Add to ListCat.6A FTP 90 Degree Inline Coupler
Providing a female-to female feed-through connection between two patch cords, the Cat.6 inline...
Details Add to List- FAQ
Category 8 Solutions for Future Networks
Category 8 RJ45 solutions are designed to support Ethernet at rate up to 40 Gbps (40GBASE-T) for short distances up to 30 meters, which is a solution primarily...
All of EXW Patch Cords Use Bare Copper Wires
All of EXW patch cords use pure bare copper wires. EXW patch cords do not use CCA (copper clad aluminum) wires nor do we recommend using patch cords made...
- Files Download
How Can 90 Degree Couplers Optimize Cable Management in High-Density Network Installations?
Our Cat.5E FTP 90 degree inline coupler's compact design fits directly into blank panels, enabling efficient cable routing in congested rack spaces. The press-fit, lead-free construction ensures reliable connections with 750-cycle lifespan while the 90-degree configuration allows flexible cable organization without sacrificing performance. Contact us to learn how our certified couplers can streamline your next structured cabling project with proven reliability.
With a robust insertion lifespan of 750 cycles and plug retention force of 11 lbf minimum, this Cat5E FTP coupler ensures long-term reliability in high-traffic network applications. The shielded construction provides superior electromagnetic interference protection, while technical specifications including 500 MΩ insulation resistance, 1,000V AC dielectric withstanding voltage, and 1.5 amp DC current rating guarantee consistent performance. Operating across temperatures from -10°C to 60°C and humidity ranges of 10% to 90% RH, this inline coupler meets the demanding requirements of network installers, data center operators, and telecommunications professionals seeking certified, high-performance connectivity solutions backed by Excellence Wire's 36 years of manufacturing expertise.